Serial | Model | HP | V/Hz | Displacement (cm3) | Cooling Capacity ASHRAE | Motor type | |||||
Test Conditions: -23.3ºC(-10F) | |||||||||||
Capacity (W) | Capacity (Btu/h) | Input Power(W) | Current (A) | COP (W/W) | EER (Btu/Wh) | ||||||
L | QD25HG | 1/12 | 220-240V/50-60Hz | 2.5 | 55 | 188 | 52 | 0.6 | 1.05 | 3.61 | RSIR |
QD30HG | 1/12 | 3.0 | 65 | 222 | 62 | 0.6 | 1.05 | 3.58 | RSIR | ||
QD35HG | 1/11 | 3.5 | 75 | 256 | 71 | 0.7 | 1.05 | 3.60 | RSIR | ||
XL | ADW43 | 1/6- | 4.3 | 110 | 375 | 100 | 1.0 | 1.10 | 3.75 | RSIR | |
ADW51 | 1/6 | 5.1 | 125 | 427 | 104 | 1.1 | 1.20 | 4.10 | RSIR | ||
ML | ADW51 | 1/6 | 5.1 | 125 | 427 | 104 | 1.1 | 1.20 | 4.10 | RSIR | |
ADW57 | 1/5- | 5.7 | 135 | 461 | 112 | 1.2 | 1.20 | 4.11 | RSIR | ||
ADW66 | 1/4- | 6.6 | 165 | 563 | 132 | 1.2 | 1.25 | 4.27 | RSIR | ||
ADW77 | 1/4 | 7.7 | 185 | 631 | 148 | 1.3 | 1.25 | 4.27 | RSIR | ||
MX | ADW66 | 1/4- | 6.6 | 165 | 563 | 132 | 1.2 | 1.25 | 4.27 | RSIR | |
ADW77 | 1/4 | 7.7 | 185 | 631 | 148 | 1.3 | 1.25 | 4.27 | RSIR | ||
ADW86 | 1/4+ | 8.6 | 200 | 682 | 160 | 1.4 | 1.25 | 4.27 | RSIR | ||
ADW91 | 1/3- | 9.1 | 220 | 751 | 176 | 1.4 | 1.25 | 4.27 | RSIR | ||
ADW110 | 1/3 | 11.0 | 275 | 938 | 203 | 1.4 | 1.35 | 4.62 | RSIR | ||
MQ | ADW91 | 1/3- | 9.1 | 220 | 751 | 162 | 1.2 | 1.35 | 4.63 | RSIR | |
ADW110 | 1/3 | 11.0 | 270 | 921 | 200 | 1.4 | 1.35 | 4.61 | RSIR | ||
ADW128 | 3/8+ | 12.8 | 320 | 1092 | 237 | 1.8 | 1.35 | 4.61 | CSIR | ||
ADW142 | 1/2- | 14.2 | 350 | 1194 | 260 | 1.9 | 1.35 | 4.59 | CSIR | ||
ADW153 | 1/2 | 15.3 | 380 | 1297 | 281 | 2.0 | 1.35 | 4.61 | CSIR | ||
ADW168 | 1/2+ | 16.8 | 430 | 1467 | 318 | 2.2 | 1.35 | 4.61 | CSIR |