Serial | Model | HP | V/Hz | Displacement (cm3) | Cooling Capacity ASHRAE | Motor type | Starting Device | |||||
Test Conditions: -23.3ºC(-10F) | ||||||||||||
Capacity (W) | Capacity (Btu/h) | lnput Power(W) | Current (A) | COP (W/W) | EER (Btu/Wh) | |||||||
L | QD35YG | 1/12 | 160V-240V/50-60Hz | 3.5 | 56 | 191 | 47 | 0.38 | 1.20 | 4.07 | RSIR | PTC Starting Relay |
QD43YG | 1/11 | 4.3 | 75 | 256 | 62 | 0.45 | 1.20 | 4.13 | RSIR | |||
QD53YG | 1/9 | 5.3 | 85 | 290 | 65 | 0.50 | 1.30 | 4.46 | RSIR | |||
QD65YG | 1/7 | 6.5 | 110 | 375 | 85 | 0.52 | 1.30 | 4.42 | RSIR | |||
QD69YG | 1/7+ | 6.9 | 120 | 409 | 92 | 0.55 | 1.30 | 4.45 | RSIR | |||
ML | QD75YG | 1/6- | 7.5 | 130 | 444 | 100 | 0.60 | 1.40 | 4.44 | RSIR | ||
QD85YG | 1/6 | 8.5 | 145 | 495 | 112 | 0.75 | 1.40 | 4.42 | RSIR | |||
QD91YG | 1/5 | 9.1 | 155 | 529 | 104 | 0.70 | 1.50 | 5.09 | RSIR | |||
QD103YG | 1/4- | 10.3 | 168 | 573 | 112 | 0.85 | 1.50 | 5.12 | RSIR | |||
QD85YG | 1/6 | 8.5 | 145 | 495 | 112 | 0.75 | 1.60 | 4.42 | RSIR | |||
MX | QD91YG | 1/5 | 9.1 | 155 | 529 | 104 | 0.70 | 1.60 | 5.09 | RSIR | ||
QD103YG | 1/4- | 10.3 | 168 | 573 | 112 | 0.85 | 1.60 | 5.12 | RSIR | |||
QD110YG | 1/4 | 11.0 | 185 | 631 | 124 | 0.95 | 1.60 | 5.09 | RSIR | |||
MQ | QD128YG | 1/3- | 12.8 | 220 | 751 | 152 | 1.05 | 1.45 | 4.94 | RSIR | ||
QD142YG | 1/3 | 14.2 | 240 | 819 | 166 | 1.15 | 1.45 | 4.93 | RSIR | |||
QD153YG | 1/3+ | 15.3 | 260 | 887 | 179 | 1.25 | 1.45 | 4.96 | RSIR |