1-MAIN FEATURE:
High efficiency
Low vibration
Good reliability
Experienced staff ensure produce of the compressors with good quality.
2-SIMPLE SPECIFICATION:
1)QDZH35G, DC series, use R134a refrigerant;
2)Voltage application 12/24VDC;
3)Cooling type: FC;
4)Application: Low Back Pressure;
5)Max Cooling Capacity: 100W;
Serial |
Model |
Displacement (cm3) |
Rotate Speed (rpm) |
Capacity |
COP |
EER |
Oil charge |
Cooling Type |
Power Supply |
Certificate |
-23.3ºC (ASHRAE) |
W |
Kcal/h |
Btu/h |
W/W |
Btu/W.h |
ml |
L |
QDZH25G |
2.5 |
2000 |
43.0 |
37.2 |
146.0 |
1.08 |
3.68 |
130 |
FC |
12/24V (DC) |
CE |
2500 |
53.0 |
45.8 |
186.0 |
1.05 |
3.58 |
3000 |
62.0 |
53.5 |
211.0 |
1.06 |
3.62 |
3500 |
72.0 |
62.2 |
245.0 |
1.04 |
3.55 |
QDZH30G |
3.0 |
2000 |
52.0 |
44.6 |
176.0 |
1.05 |
3.58 |
2500 |
64.0 |
55.0 |
217.0 |
1.05 |
3.58 |
3000 |
75.0 |
64.3 |
254.0 |
1.06 |
3.62 |
3500 |
87.0 |
74.7 |
295.0 |
1.04 |
3.55 |
QDZH35G |
3.5 |
2000 |
60.0 |
51.9 |
204.6 |
1.08 |
3.68 |
2500 |
73.0 |
63.1 |
248.9 |
1.07 |
3.65 |
3000 |
86.0 |
74.4 |
293.2 |
1.06 |
3.62 |
3500 |
100.0 |
86.5 |
341.0 |
1.05 |
3.58 |
QDZH43G |
4.3 |
2000 |
80.0 |
69.1 |
273.0 |
1.15 |
3.92 |
2500 |
96.0 |
82.9 |
327.6 |
1.2 |
4.09 |
3000 |
115.0 |
99.4 |
392.4 |
1.25 |
4.27 |
3500 |
138.0 |
119.2 |
470.9 |
1.25 |
4.27 |
MK |
QDZH50G |
5.0 |
2000 |
87.0 |
75.2 |
296.8 |
1.17 |
3.99 |
180 |
2500 |
104.0 |
89.9 |
354.8 |
1.13 |
3.86 |
3000 |
130.0 |
112.3 |
443.6 |
1.35 |
4.61 |
3500 |
163.0 |
140.8 |
556.2 |
1.2 |
4.09 |
QDZH65G |
6.5 |
2000 |
120.0 |
103.6 |
409.4 |
1.2 |
4.09 |
2500 |
150.0 |
129.6 |
511.8 |
1.2 |
4.09 |
3000 |
180.0 |
155.5 |
614.2 |
1.2 |
4.09 |
3500 |
210.0 |
181.4 |
716.5 |
1.2 |
4.09 |
3-CERTIFICATE: CE.
4-STORAGE CONDITION:
1)Compressor should be stored in a dry and drafty place
2)Compressor should not be tilted or inverted in storage, transportation and
Installation; Collision should be avoided.
3)Rubber plugs should not be pulled out from discharge tube before installation so
As to avoid impurity and humidity. During the installation, the rubber plugs of
Discharge tube should be pulled out at first, then the rubber plugs of process
Tube, and the rubber plugs of process suction tube at last. The installation should
Be completed within 10 min after that.
4)The accessories (eg. Starter, thermal protection etc. ) are nor installed into
The compressor while delivery, but in the accessory case. Be sure to select the
Corresponding starter and thermal protection models rightly.