Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System

Product Details
Customization: Available
Material: Metal
Usage: Commercial Refrigerator & Freezer
Still deciding? Get samples of US$ 4/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2005

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
300
Year of Establishment
2009-02-09
  • Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System
  • Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System
  • Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System
  • Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System
  • Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System
  • Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System
Find Similar Products
  • Overview
  • Product Description
  • Our Advantages
  • Product Parameters
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
SPLC-Y Series
Product Name
Splc-Y Series Liquid Receiver
Max. Working Pressure
30 Bar
Refrigerant
Suitable with Hfc, Hcfc Refrigerants(R134A, etc.)
Certification
CE Certified
Installation Method
Horizontal or Vertical
Transport Package
Sikelan/Neutral Package to Export
Trademark
SIKELAN
Origin
China
HS Code
8421299090
Production Capacity
2000000

Product Description

Product Description

SIKELAN oil receivers are used in "low and high pressure oil control systems". Due to system design, loading and defrosting cycle, the changing oil mass can be send back by oil separator, thus, a safety oil receiver is required for the operation of oil control system. In the oil receiver, any refrigerant trapped within the oil is boiled-off and the oil is cooled and kept available.

SIKELAN oil receivers are normally equipped with sight glasses with float ball level indicators, for upper and lower level indication, and with two shut off valves, the top valve receives valve from oil separator, and the bottom valve sends oil to the oil regulator.
Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System

Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System
Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System

Features:
- Max. Allowable operating pressure: 3.0Mpa
- Refrigerant: suitable with HFC & HCFC Refrigerants and associated oil (R134A, R404A, R507, R407A, R407C, R22 etc)
- SIKELAN oil receivers are CE listed.
SIKELAN oil receivers are supplied with:
- Two/Three sight glasses with level indicator balls inside, to check the oil level in the receiver. These glassed arealready screwed on the vessel.
- Two rotalock valves to easy connect oil fill and oil drain. These glasses are not mounted on the receiver but are supplied in the package, completed by the proper gaskets, The customer can assemble the rotalock valves on thereceiver according to his preferred working position.
- A 3/8'' SAE Flare connection on the top of the receiver to allow the assembling of a pressure differential check valve. Pressure difterential check valve is not sunplied with receiver: if it's necessarv to maintain a positive differential pressure between the receiver and the compressor crankcase the customer can select SIKELAN Pressure differential check valve. Screw the differential valve onto the 3/8'' SAE connection, remember to use PTFE gasket between receiver and valve, The receiver body is manufactured from steel pipe of adequate thickness. Top and botom are also made from carbon steel.

 
Our Advantages

Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control SystemSight Glasses Liquid Oil Refrigeration Receiver for Oil Control System

Product Parameters
MODEL INLET & OUTLET(IN) A(mm) B(mm) C(mm) D(mm) E(mm) F(mm) Sight Glass QTY Oil Storage Volume(L)
SPLC-Y6 3/8 338 94 150 165 - - 2 6
SPLC-Y8 3/8 438 109 220 165 - - 2 8
SPLC-Y10 3/8 548 131 285 165 - - 2 10
SPLC-Y12 3/8 638 139 360 165 - - 2 12
SPLC-Y14 1/2 738 110 518 165 259 - 3 14
SPLC-Y19 1/2 580 140 300 219 - - 2 19
SPLC-Y23 5/8 700 140 420 219 210 - 3 23
SPLC-Y10CL 3/8,1/2 548 144 260 165 90 208 2 10
SPLC-Y20CL 3/8,5/8 660 180 300 219 130 200 2 20
→ More Filters Please Contact Us!
Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System

 
Company Profile

Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System
Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System

Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System

 

Certifications

With abundant technique force,we have our own researching, developing, manufacturing, inspecting and testingcenters, and imported the international advanced high-tech equipments. Our company has passed the ISO9001,ISO14001,OHS18001 international management system certificates. The products have got UL,ETL,CE,CB,and CCC certificates. Our products are not only selling strongly in more than 30 provincesand municipality,but also largely exporting to Europe,America,Australia,Middle East, Africa and South Asia. We have won an excellent reputation from the customers and friends by our product quality,price versus performance ratio and service.
Sight Glasses Liquid Oil Refrigeration Receiver for Oil Control System

FAQ

Q1: Are you a manufacturer or trader?
A1: Zhejiang Maidi Refrigeration Technology Co., Ltd. is a Hi-tech enterprise. We own the standard plant and office building which covering 21, 000 square meters. With abundant technique force, we have our own researching, developing, manufacturing, inspecting and testing centers, and imported the international advanced equipments.

Q2: How to match sikelan filter to refrigeration?
A2: We have a professional team of engineers who provide technical support and online guidance on product installation and replacement.

Q3: How do you ensure quality?
A3: We have a dedicated product research and testing center with authoritative quality management system certification: ISO9001/ISO14001/OHS18001.

Q4:What's sikelan filter usage scenario?
Q4:Our product could use in refrigerators, air conditioners, and cold storage room.

Q5: How much does a refrigeration part cost?
A5: Factory price for you, not cheapest but the competitive price with good quality.

Q6:What certifications do sikelan have?
A6:We have UL, CCC, CE, CB, ETL, TUV, RoHS certifications in compressor.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now